亚洲欧美日韩中文无线码,精品一区二区三区高清免费不卡,国产精品色午夜免费观看,国产精品va在线一区二区

產(chǎn)品中心

人Ⅶ型膠原(COL7)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK3163
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human COL7(Collagen Type VII) ELISA Kit
Reactivity: Human
Alternative Names: COL7-A1; COL7A1; EBD1; EBDCT; EBR1; Long-chain collagen; Epidermolysis Bullosa,Dystrophic,Dominant And Recessive; Collagen Alpha-1(VII)chain
Assay Type: Sandwich
Sensitivity: 5.9 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Developmental science;Nutrition metabolism;Bone metabolism;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human COL7. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human COL7. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human COL7, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human COL7 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.027 1.940
500.00 1.609 1.522
250.00 1.186 1.099
125.00 0.861 0.774
62.50 0.456 0.369
31.25 0.387 0.300
15.63 0.232 0.145
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant COL7 and the recovery rates were calculated by comparing the measured value to the expected amount of COL7 in samples.
Matrix Recovery range Average
serum(n=5) 95-105% 100%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 92-105% 98%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of COL7 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 95-103% 97-105% 88-97%
EDTA plasma(n=5) 83-95% 85-96% 87-101% 83-95%
Heparin plasma(n=5) 98-105% 86-95% 94-103% 95-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
主站蜘蛛池模板: 黄大仙区| 越西县| 六安市| 革吉县| 蛟河市| 石渠县| 筠连县| 昌黎县| 兴和县| 林甸县| 平度市| 米泉市| 石泉县| 双柏县| 深水埗区| 盱眙县| 溆浦县| 万山特区| 涟水县| 宜兰县| 旬阳县| 古交市| 淅川县| 务川| 白玉县| 平定县| 清河县| 石台县| 南京市| 浙江省| 灵台县| 甘德县| 应城市| 二连浩特市| 科尔| 白朗县| 涪陵区| 乌拉特后旗| 都江堰市| 邵东县| 蓝山县|