亚洲欧美日韩中文无线码,精品一区二区三区高清免费不卡,国产精品色午夜免费观看,国产精品va在线一区二区

產(chǎn)品中心

人基質(zhì)金屬蛋白酶12(MMP12)酶聯(lián)免疫吸附檢測試劑盒
ELK2355
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human MMP12(Matrix Metalloproteinase 12) ELISA Kit
Reactivity: Human
Alternative Names: MME; HME; ME; Macrophage Metalloelastase; Macrophage Elastase
Assay Type: Sandwich
Sensitivity: 0.12 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Tumor immunity;Infection immunity;
Uniprot ID: P39900
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MMP12. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MMP12. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MMP12, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MMP12 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 1.990 1.886
10.00 1.506 1.402
5.00 1.073 0.969
2.50 0.839 0.735
1.25 0.523 0.419
0.63 0.312 0.208
0.32 0.249 0.145
0.00 0.104 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MMP12 and the recovery rates were calculated by comparing the measured value to the expected amount of MMP12 in samples.
Matrix Recovery range Average
serum(n=5) 89-107% 98%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 78-90% 84%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MMP12 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 91-103% 87-98% 95-101%
EDTA plasma(n=5) 89-99% 83-95% 98-104% 96-106%
Heparin plasma(n=5) 85-100% 84-98% 95-101% 88-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
主站蜘蛛池模板: 陇南市| 自贡市| 昌乐县| 昆山市| 无锡市| 乌海市| 定州市| 阿合奇县| 贵德县| 华蓥市| 沙湾县| 丹棱县| 台州市| 台中市| 虞城县| 黄大仙区| 刚察县| 大邑县| 重庆市| 西青区| 阿荣旗| 五常市| 秀山| 祁连县| 武威市| 鱼台县| 伊川县| 荔波县| 平罗县| 临泽县| 呼图壁县| 京山县| 沾化县| 建宁县| 安泽县| 栖霞市| 新乡市| 巩留县| 惠州市| 榆中县| 婺源县|